Threaded Inline

Description

Stainless Steel threaded heaters for heating high-pressure air or inert gases to 1400°F (760°C). Sizes from 3/8”
to 2-1/2” diameter, and in wattages from 1.6 to 18 Kilowatts. If operated correctly, the heater will operate
continuously for 5000 hours or longer.

Specifications

  • Air temperatures to 1400˚F (760˚C)
  • For applications requiring high pressure air
  • Both ends threaded 3/8″, 1/2″, 1-1/4″, and 2-1/2″ NPT
  • 304 Stainless Steel housing

CE compliant

 

The Inline High Temperature 900°C:

Installation

  • Securely mount the heater.

FOR 3/8”, ½”, AND 1 ¼” HEATER ONLY (#038821, 038822, 038823, 038824, 038825, AND 038826):

  • There are two feedthroughs on the heater. Each feedthrough has three wires (marked 1, 2, or 3) coming out of it.
  • Connect one power lead to one heater electrical feedthrough (or one lead wire) and connect the other power
    lead to the other electrical feedthrough. (or other lead wire).
  • Connect the ground wire to the green grounding nut on the heater body.
  • Connect the air source to the heater.
  • If a thermocouple is used, ensure that it is located within one inch from the heater exit.

FOR 2 ½” HEATER ONLY (#063007):
18,000 WATT – 240 VOLT – SINGLE PHASE OPERATION:

  • Each of the two heater feedthroughs has three wires (marked 1, 2, or 3) coming out of it.
  • Connect one side of power to all three leads that exit one feedthrough (1, 2, and 3 together).
  • Connect the other side of the power to all three leads that exit the second feedthrough (1, 2, and 3 together).
  • Make sure the heater is properly grounded. Note: Run single phase, 240 volts, the heater will draw 75 Amps.
  • Connect the air source to the heater.
  • If a thermocouple is used, ensure that it is located within one inch from the heater exit.

18,000 WATT – 240 VOLT – THREE PHASE OPERATION:

  • Each of the two heater feedthroughs have three wires (marked 1, 2, or 3) coming out of it.
  • Connect the elements in a standard delta configuration. (Connect one power lead to each of the following pairs: 1-2, 2-3, 3-1).
  • Make sure the heater is properly grounded.
  • Note: Run three phase, 240 volts, the heater will draw 44 Amps.
  • Connect the filtered air source to the heater.
  • If a thermocouple is used, ensure that it is located within one inch from the heater exit.

 

Datasheet : Inline Manuel

The Inline high temperature #076339 8 kW / 240V is able to heat 350Lpm of air at 900°C under pressure of 7 bars.